As the professional manufacture, we would like to provide you high quality 24S 86.4V 15A Hardware BMS Dual Lithium ion Battery Packs for E-Unicycles. And we will offer you the best after-sale service and timely delivery.
This FY•X high quality 24S 86.4V 15A Hardware BMS Dual Lithium ion Battery Packs for E-Unicycles is a protective plate solution specially designed by Huizhou Feiyu New Energy Technology Co., Ltd. for the 24-string battery pack of unicycles; it can be applied to different chemical propertiesLithium batteries, such as lithium ion, lithium polymer, etc. The protection board has strong load capacity, and the maximum continuous current can be 30A.
●24 batteries are protected in series;
● Charging and discharging voltage, temperature and other protection functions;
● Discharge alarm function;
● The switch controls the on/off function.
● Shut down to reduce power consumption.
Figure 1: BMS front view
Figure 2: Physical picture of the back of BMS
Details |
Min. |
Typ. |
Max |
Error |
Unit |
||
Battery |
|||||||
Battery Gas |
LiCoxNiyMnzO2 |
|
|||||
Battery Links |
24S |
|
|||||
Absolute Maximum Rating |
|||||||
Input Charging Voltage |
|
100.8 |
|
±1% |
V |
||
Input Charging Current |
|
2 |
5 |
|
A |
||
Output Discharging Voltage |
67.2 |
86.4 |
102 |
|
V |
||
Output Discharging Current |
|
|
30 |
|
A |
||
Continuous Output Discharging Current |
≤30 |
A |
|||||
Ambient Condition |
|||||||
Operating Temperature |
-20 |
|
75 |
|
℃ |
||
Humidity (No Water-Drop) |
0% |
|
|
|
RH |
||
Storage |
|||||||
Temperature |
-40 |
|
85 |
|
℃ |
||
Humidity (No Water-Drop) |
0% |
|
|
|
RH |
||
Protection Parameter |
|||||||
Over-Charge Voltage Protection |
|
4.250 |
|
±30mV |
V |
||
Over-Charge Voltage Protection Delay Time |
|
1 |
|
±0.5 |
S |
||
Over-Charge Voltage Protection Release |
|
4.150 |
|
±50mV |
V |
||
Over-Discharge Voltage Protection |
|
2.800 |
|
±80mV |
V |
||
Over-Discharge Voltage Protection Delay Time |
|
20 |
|
±3 |
S |
||
Over-Discharge Voltage Protection Release |
|
3.000 |
|
±100mV |
V |
||
Charging Temperature |
0 |
60 |
|
±5 |
℃ |
||
Charging Temperature Protection Release |
5 |
55 |
|
±5 |
|
||
Discharging Over-Temperature |
-20 |
65 |
|
±5 |
℃ |
||
Discharging Temperature Protection Release |
-15 |
60 |
|
±5 |
℃ |
||
|
|||||||
Current Consumption |
|||||||
PowerConsumption on |
|
|
3 |
|
mA |
||
SleepConsumption |
|
150 |
200 |
|
uA |
||
ShipConsumption |
|
|
80 |
|
uA |
Figure 7: Protection principle block diagram
Figure 10: Dimensions 220*140 Unit: mm Tolerance: ±0.5mm
Protection board thickness: less than 9mm (including components)
Figure 11: Protection board wiring diagram
Item |
Details |
|
C+ |
Charging Positive Port. |
|
P+ |
Discharging Positive Port. |
|
B+ |
Connect to Positive Side of the pack. |
|
B6 |
Connect to Positive Side of Cell 6 |
|
B7 |
Connect to Positive Side of Cell 7 |
|
B8 |
Connect to Positive Side of Cell 8 |
|
B9 |
Connect to Positive Side of Cell 9 |
|
B12 |
Connect to Positive Side of Cell 12 |
|
B13 |
Connect to Positive Side of Cell 13 |
|
B14 |
Connect to Positive Side of Cell 14 |
|
B15 |
Connect to Positive Side of Cell 15 |
|
B18 |
Connect to Positive Side of Cell 18 |
|
B19 |
Connect to Positive Side of Cell 19 |
|
B- |
Connect to Negative Side of the pack. |
|
P- |
Discharging Negative Port. |
|
C- |
Charging Negative Port. |
|
J1 |
1 |
Connect to Negative Side of Cell 1 |
2 |
Connect to Positive Side of Cell 1 |
|
3 |
Connect to Positive Side of Cell 2 |
|
4 |
Connect to Positive Side of Cell 3 |
|
5 |
Connect to Positive Side of Cell 4 |
|
6 |
Connect to Positive Side of Cell 5 |
|
7 |
Connect to Positive Side of Cell 10 |
|
8 |
Connect to Positive Side of Cell 11 |
|
J2 |
1 |
Connect to Positive Side of Cell 16 |
2 |
Connect to Positive Side of Cell 17 |
|
3 |
Connect to Positive Side of Cell 20 |
|
4 |
Connect to Positive Side of Cell 21 |
|
5 |
Connect to Positive Side of Cell 22 |
|
6 |
Connect to Positive Side of Cell 23 |
|
7 |
Connect to Positive Side of Cell 24 |
|
CTRL/PG |
Parallel signal/alarm signal ground wire |
|
ONF |
switch signal |
|
UD |
warning signal |
|
NTC |
Temperature detection probe |
Figure 12: Schematic diagram of battery connection sequence
Warning: When connecting the protective plate to the battery cells or removing the protective plate from the battery pack, the following connection sequence and regulations must be followed; if operations are not performed in the required order, the components of the protective plate will be damaged, resulting in the protective plate being unable to protect the battery. core, causing serious consequences.
Preparation: According to the definition shown in Figure 11, connect the corresponding voltage detection cable to the corresponding battery core. Please pay attention to the order in which the sockets are marked.
Steps to install protective board:
Step 1: Weld the P, C-, CTRL, ONF, PG, UD- lines to the corresponding positions of the protection board without connecting the charger and load.
Step 2: Connect the negative pole of the battery pack to B- of the protection board;
Step 3: Connect the battery pack and battery rows to J1 of the protection board;
Step 4: Connect the battery pack and battery rows to J2 of the protection board;
Step 5: Connect the positive terminal of the battery pack to B+ of the protection board;
Step 6: Connect the battery detection voltage cables B6, B7, B8, B9, B12, B13, B14, B15, B18, B19 in sequence;
Steps to remove the protective plate:
Step 1: Disconnect all chargers\loads
Step 2: Remove the battery detection voltage cables B19, B18, B15, B14, B13, B12, B9, B8, B7, B6 in sequence.
Step 3: Remove the connecting wire connecting the positive electrode of the battery pack from the B+ pad of the protective plate
Step 4: Unplug the battery pack and battery strip connector J2;
Step 5: Unplug the battery pack’s battery strip connector J1;
Step 6: Remove the connecting wire connecting the negative electrode of the battery pack from the B- pad of the protective plate
Additional notes: Please pay attention to electrostatic protection during production operations.
|
Device type |
Model |
Encapsulation |
Brand |
Dosage |
Location |
1 |
Chip IC |
SH367107X/028XY-AAD11 |
TSSOP28 |
Zhongying |
1PCS |
U10 |
2 |
Chip IC |
SH367108X/038XY-AAD11 |
TSSOP38 |
Zhongying |
1PCS |
U7 |
3 |
Chip IC |
N76E003AT20 |
TSSOP20 |
New Tang Dynasty |
1PCS |
U9 |
4 |
MOS tube |
CRST085N15N |
TO263 |
China Resources Micro |
8pcs |
M3,4,5,6,7,8,9,13 |
5 |
PCB |
Fish24S002(V12) V1.0 |
220*140*1.6mm |
brand |
1PCS |
|
Note: If SMD transistors and MOS tubes are out of stock, our company may replace them with other models of similar specifications.
1 Huizhou Feiyu New Energy Technology Co., Ltd. logo;
2 Protection board model - (This protection board model is Fish24S002, other types of protection boards are marked, there is no limit to the number of characters in this item)
3. The number of battery strings supported by the required protection board - (this model of protection board is suitable for 24S battery packs);
4 Charging current value - 5A means the maximum support for continuous 5A charging;
5 Discharge current value - 30A means maximum support for continuous 30A charging;
6. Balance resistance size - directly fill in the value, such as 100R, then the balancing resistance is 100 ohms. This protection board does not support balancing;
7 Battery type - one digit, the specific serial number indicates the battery type as follows;
1 |
Polymer |
2 |
LiMnO2 |
3 |
LiCoO2 |
4 |
LiCoxNiyMnzO2 |
5 |
LiFePO4 |
8 Communication method - one letter represents a communication method, I represents IIC communication, U represents UART communication, R represents RS485 communication, C represents CAN communication, H represents HDQ communication, S represents RS232 communication, 0 represents no communication, product UC Represents UART+CAN dual communication;
9 Hardware version - V1.0 means the hardware version is version 1.0.
10 The model number of this protection board is: WH-Fish24S002-24S-5A-30A-0-4-0-V1.0. Please place the order according to this model number when placing bulk orders.
1. When performing charge and discharge tests on the battery pack with the protective board installed, please do not use a battery aging cabinet to measure the voltage of each cell in the battery pack, otherwise the protective board and battery may be damaged. .
2. This protection board does not have a 0V charging function. Once the battery reaches 0V, the battery performance will be severely degraded and may even be damaged. In order not to damage the battery, the user should not charge the battery for a long time (the battery pack capacity is greater than 15AH, and the storage exceeds 1 Months) When not in use, it needs to be charged regularly to replenish the battery; when in use, it must be charged in time within 12 hours after being discharged to prevent the battery from being discharged to 0V due to self-consumption. Customers are required to have an obvious sign on the battery casing that the user regularly maintains the battery.
3. This protection board does not have reverse charging protection function. If the polarity of the charger is reversed, the protection board may be damaged.
4. This protective board shall not be used in medical products or products that may affect personal safety.
5. Our company will not be responsible for any accidents caused by the above reasons during the production, storage, transportation and use of the product.
6. This specification is a performance confirmation standard. If the performance required by this specification is met, our company will change the model or brand of some materials according to the order materials without further notification.
Note: After your company receives the prototype and specifications, please reply promptly. If there is no reply within 7 days, our company will regard your company as having recognized the specifications and send the prototype. If your order exceeds 50 PCS, you need to sign back the acknowledgment letter. If you do not sign back, our company will also regard your company as having approved this specification and send the sample machine. The pictures in the specification are of general models and may be slightly different from the sample delivered. Huizhou Feiyu New Energy Technology Co., Ltd. reserves the right of final interpretation of this specification.